Cable Hta Cis 24kv 3X240mm2

  • Model NO.: Hta Cis 24kv 3X240mm2
  • Application: Overhead, Underground
  • Sheath Material: PVC
  • Material Shape: Round Wire
  • Certification: ISO9001, CE, UL, CCC, RoHS, VDE
  • Size: 16mm2,25mm2,35mm2,50mm2,70mm2,95mm2,120mm2,150mm2
  • Shield: Aluminum Tape Shield
  • Phase Conductor: Stranded Aluminum Wire
  • Trademark: Zhengzhou Yifang Cable Co., Ltd.
  • Specification: ISO CE SABS
  • HS Code: 8544492100
  • Conductor Type: Stranded
  • Conductor Material: Aluminum
  • Insulation Material: XLPE
  • Range of Application: Overhead Power Transmission
  • Brand: Yifang
  • Insulation: XLPE
  • Sheath: PVC
  • Beutral Conductor: Insulated Stranded Steel Wire/ AAAC/ACSR
  • Transport Package: Wooden Drum
  • Origin: Henan, China
Cable Hta Cis 24kv  3X240mm2
The basic construction is as follows: 
3 power cores consisting of standard aluminium conductors, insulated with 

XLPE insulation 
+ One sheath lighting aluminium conductor with XLPE insulation (optional) 
+ One steel wire stranded with PVC Insulation ( covered) 

The messenger conductor can be of galvanised steel wire The purpose of messenger wire is 
A) It acts as load bearing wire. 
B) It acts as earth or neutral conductor. 

It meets or exceeds the following specifications: 
1. Aluminum Wire, 1350-H19 for Electrical Purposes. 
2. Aluminum Conductors, Concentric-Lay-Stranded. 
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR) 
4. Concentric-Lay-Stranded 6201-T81 Conductors 

5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire. 

It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
 

Code world

AWG or kcmil

Bare neutral Messenger

Phase Conductor

weight
(km/kg)

Allowabile Ampactaition(A)

ACSR

Rated Strengthils

AAC

Insulation thickness

Number

Dia
Mm

Number

Dia
Mm

XLPE

PE

Pekingese
Collie
Dachshund
Spariel
Doberman
Malemute

1*6AWG+1*6AWG
1*8AWG+1*8AWG
1*4AWG+1*4AWG
1*4AWG+1*4AWG
1*2AWG+1*2AWG
1*1/0AWG+1*1/0AWG

7
7
7
7
7
7

1.56
1.56
1.96
1.96
2.47
3.12

563
563
881
881
1350
1990

1
7
1
7
7
19

4.11
1.58
5.19
1.96
2.47
1.89

1.14
1.14
1.14
1.14
1.14
1.52

92
94
139
141
216
347

85
85
115
115
150
205

70
70
90
90
120
160
 

Code world

AWG or kcmil

Bare noutral Messenger

Phase Conductor

weight
(km/kg)

Allowabile Ampactaition(A)

ACSR

Tensile strength

AAC

Insulation thickness

Number

Dia
Mm

Number

Dia
Mm

Number

Dia
Mm

XLPE

PE

Setter
Shepherd
Eskimo
Temier
Chew
Bull

1*6AWG+1*6AWG
1*8AWG+1*8AWG
1*4AWG+1*4AWG
1*4AWG+1*4AWG
1*2AWG+1*2AWG
1*1/0AWG+1*1/0AWG

1
1
1
1
1
1

1.68
1.68
2.12
2.12
2.67
3.37

6
6
6
6
6
6

1.68
1.68
2.12
2.12
2.67
3.37

1190
1190
1860
1860
2850
4380

1
7
1
7
7
19

4.11
1.58
5.19
1.96
2.47
1.89

1.14
1.14
1.14
1.14
1.14
1.52

111
113
171
173
266
427

85
85
115
115
150
205

70
70
90
90
120
160
 

Code world

AWG or kcmil

Bare neutral Messenger

Phase Conductor

weight
(km/kg)

Allowabile Ampactaition(A)

ACSR

Tensile strength

AAC

Insulation thickness

Number

Dia
Mm

Number

Dia
Mm

XLPE

PE

Chihuahua
Visla
Harrier
Whippet
Schnauzer
Heeler

1*6AWG+1*30.58
1*8AWG+1*30.58
1*4AWG+1*48.69
1*4AWG+1*48.69
1*2AWG+1*77.47
1*1/0AWG+1*123.3

7
7
7
7
7
7

1.68
1.68
2.12
2.12
2.67
3.37

1110
1110
1760
1760
2800
4460

1
7
1
7
7
19

4.11
1.58
5.19
1.96
2.47
1.89

1.14
1.14
1.14
1.14
1.14
1.52

98
100
149
151
231
372

85
85
115
115
150
205

70
70
90
90
120
160

Product Description


SPD Surge Protective Device,Lightning Surge Protector
Surge Protection Device (SPD)

 
It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.
 
Surge protective Device Model Selection
 
With the impact of international information flow, the rapid development of microelectronic science and technology, communication, computer and automatic control technology, make the building start to go for high quality, high functional area, formed a new building style-intelligent building. As inside the intelligent building there are lot of information system, <<Building lightning protection design norm>> GB50057-94(2002 vision)(hereafter brief as <<lightning protection norm>>) put forward the relative requirement to install the surge protective device, to ensure the information system safely and stable running.
SPD essentially is a equipotential connection material, its model selection is according to the different lightning protection area, different lightning electromagnetic pulse critical and different equipotential connection position, decide which kind of SPD used in the area, to achieve the equipotential connection with the common earth electrode. Our statement will based on SPD's maximum discharge current Imax, continuous operating voltage Uc, protection voltage Up, alarm mode etc.
As per << Lightning Protection Norm>> item 6.4.4 stipulation "SPD must can withstand the expected lightning current flow and should confirm to the additional two requirements: the maximum clamp voltage during surge across, capable to extinguish the power frequency follow-on current after lightning current across."  That is the value of SPD's max. clamp voltage add its induction voltage of two ends should be same with the system's basic insulation level and the equipment allowed max. surge voltage. 
 
SPD for Power Supply System Series Selection Guide
 
The installation of SPD at each lightning protection zone, according to the standard of Low Voltage Electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose. 
SPD for power supply system specification selection principle 
Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage. 
TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)
TN System: Uc≥1.15Uo
IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)
Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
SP1 Series
 
Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
Normal range: -5ºC~+40ºC
Extend range: -40ºC~+80ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust) 
 
Classification
 
-As per Nominal Discharge Current: 
5,10,20,30,40,60KA(8/20µs)
- As per Maximum continuous operating voltage: 
275V,320V,385V,420V,440V,460V
- As per to poles
1P,1P+N,2P,3P,3P+N,4P
- As per auxiliary functions:
a. With remote signal output ( remote alarm function)
b. Without remote signal output
 
Selection Principle
 
- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;
- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;
- As per to the different earthing system and protection mode to select the specification accordingly;

Product Features

1, built-in over-current overheating, temperature control circuit technology.

2, the module design, easy installation, online replacement.

3, low leakage current, fast response time, low residual voltage.

4, alarm indication device, green (normal) v red (fault).

Model/Technical Parameters WR-B60 WR-B80 WR-B100 WR-B120 WR-B150
Rated Operating Voltage Un (V ~) 220V 380V 220V 380V 220V 380V  220V 380V   220V 380V  
Maximum Continuous Operating Voltage Uc (V ~) kV 385V 420V 385V 420V 385V 420V  385V 420V 385V 420V
Voltage Protection Level Up (V ~) kV ≤1.8≤2.2 ≤2.4≤2.5 ≤2.5≤3.2  â‰¤3.4≤3.7  ≤4.0≤4.5

 Maximum Discharge

Current Imax(8/μ20μs)kA

60 80 100 120 150

Nominal Discharge

 Current In(8/μ20μs)kA

30 40 60 80 100
Response Time <25 <100
L/N(mm²)The Cross Section Of L/N Line 16,25 16,25 16,25 16,25 25,35
 PE (mm²)The Cross Section Of PE Line 16,25  25,35  25,35  25,35 35
Fuse or Switch (A)  63A  63A  63A,100A 63A,100A 63A,125A
The Line Section of Communication and Alarm (mm²)                                   ≥ 1.5   

Operating

Environment-C

                         (-40ºC~-+85ºC)
Relative humidity 25 ºC                                   ≤95%
installation Standard Rail35mm
Material of Outer Covering Fiber Glass Reinforced Plastic

Surge Protection Device SPD

Surge Protector SPD,Surge Protection Device SPD

Wenzhou Korlen Electric Appliances Co., Ltd. , http://www.korlenelectric.com